Insulation Calculator
Work out how much insulation you need for a wall, ceiling or floor, and how many packs that is.
No results yet.
Formula and method
The insulated area comes from room dimensions or from a known coverage area. Multiplying it by the thickness and the number of layers gives the volume, and dividing the layered area by the package coverage gives the pack count. The waste allowance is applied before rounding up.
Insulate by construction, not by floor area
The area that matters is the area of the building envelope you are insulating, measured along the construction. A pitched roof at 35° has 22 % more surface than the ceiling below it, and a wall with a bay window has more than its plan length suggests. Measuring the floor and using that number under-orders every roof in the house.
Where a drawing or a survey exists, enter the measured area directly instead of the room dimensions. The rectangular model in the calculator is a fallback for when you have a tape measure and nothing else, and it is only as good as the room is regular.
Layers, joints and the thickness that actually works
Insulation is supplied in fixed thicknesses, so 150 mm is a 100 mm layer plus a 50 mm layer, with the joints staggered between them. Staggering is not a detail: if the joints line up, the gap becomes a straight path for air, and the declared thermal resistance never appears in the finished wall.
Compressing mineral wool to fit a shallower space is the other common error. Squeezing 150 mm into 120 mm raises the density and lowers the lambda, so the U-value gets worse in a way that is invisible after the boards go back up.
What the number does not include
Thermal bridging is outside this calculation. Timber studs occupy 10 to 15 % of a framed wall and conduct two to three times better than mineral wool, so the whole-wall U-value is worse than the material's. Steel studs and concrete lintels are worse still.
Vapour control, airtightness tape, fixings and the membrane are separate lines with their own 10 to 15 % overlap allowance. Skipping the tape to save money is the decision that turns a good insulation job into a condensation problem two winters later.
How to measure the inputs
- Measure the room length, width and height, or enter a known coverage area.
- Decide the thickness in millimetres and convert to the unit you will enter.
- Read the coverage per pack from the packaging before ordering.
Worked example
Room length 13.12 ft; Room width 16.4 ft; Room height 8.2 ft; Insulation thickness 7.87 in; Coverage per package 43.06 ft²; Number of layers 2; Waste 10 % → Insulation packs: 11
Reference data
| Material | λ, W/(m·K) | Thickness, mm |
|---|---|---|
| Mineral wool | 0.04 | 150 |
| EPS | 0.04 | 160 |
| XPS | 0.03 | 140 |
| PUR | 0.02 | 100 |
| Wood fibre | 0.05 | 190 |
Thickness is λ / U without surface films, so it reads 5–10 % higher than a wall build-up calculation.
Practical tips
- Keep a small gap between insulation and the roof covering to allow ventilation.
- Do not compress insulation to fit: compression reduces performance.
- Wear gloves and a mask when handling mineral wool.
Sources
- СП 50.13330.2012 — Тепловая защита зданий
- EN 13162 — Mineral wool products
Checked and updated October 22, 2026